2b. NORMAL SERVICE: the pump is running
The assembly requires water. One or more taps are turned on. TEEPRES
detects a flow; the assembly pressure is normally higher than the START-UP
pressure, but it may also be lower.
Press briefly or hold down = The pump is stopped and
put OUT OF SERVICE. For instructions on how to reacti-
vate the pump, see point 3
The taps are turned off = If there is no flow for a few se-
conds, the pump is stopped.
3. OUT OF SERVICE
The pump has been stopped manually. The pump will remain inactive until a
new command is given.
Press briefly = nothing happens
Hold down = the pump resumes NORMAL SERVICE.
See points 2a-2b.
4a. ERROR: stopped temporarily due to DRY RUNNING (see NOTE 1)
TEEPRES
ped it TEMPORARILY.
Press briefly = the pump is started and manually and
resumes NORMAL SERVICE. See points 2a-2b.
Hold down = the pump is put OUT OF SERVICE.
For instructions on how to reactivate the pumpe, see point 3
4b. ERROR: temporary shut down due to FREQUENT START-UP (see NOTE 2)
TEEPRES
fore stopped it TEMPORARILY.
Press briefly = the pump is started manually and resumes
NORMAL SERVICE. See points 2a-2b.
Hold down = the pump will not restart and goes OUT OF
ORDER. The pump is OUT OF SERVICE. For instructions
on how to reactivate the pump, see point 3.
7. PARTS AND DIMENSIONS
1 – TEEPRES® body
2 – Cover with
TEEPRES® board
3 – Valve unit
4 – Pressure gauge
(Depends on model)
5 – Cable gland
has detected that the pump is dry running and has therefore stop-
®
has detected that the pump starting-up too often and has there-
®
English 7
®