TROUBLESHOOTING
ISSUE
Drum filter rinses too often
Drum filter doesn't rinse automatically
Drum doesn't turn while rinsing
Drum keeps turning
Cleaning pump doesn't work
Cleaning pump keeps running
GUARANTEE
The product is guaranteed for 5 years from the date of purchase on materials and manufacturing defects. Every effort has been made during the manufacturing process to ensure the drum
filter meets the rigid quality standards. However, should you need to make a claim under this Guarantee, please return the product to the place of purchase with the original receipt as proof of
purchase. Claims brought about by incorrect installation or operation, inadequate maintenance, the effects of frost, inexpert attempts at repair, the use of force, wrongful acts by a third-party,
overloading and foreign objects, as well as all damage to parts resulting from wear and tear, are not covered by this guarantee. By virtue of the Product Liability Act, we are not liable for damage
caused by our equipment, if this is the result of an inexpert repair.

CORRECT DISPOSAL OF THIS PRODUCT

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health
from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection
systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
CAUSE
• Screen clogged
• Flow too high
• Sensor position too high
• Water level too low
• Screen clogged
• Motor broken
• Motor overheated
• Relay stuck (broken)
• Plug is in wrong socket
• Cleaning pump broken
• Plug is in wrong socket
• Relay stuck (broken)
SOLUTION
• Clean screen with citric acid, if heavily soiled, use hydrochloric acid (30%)
• Regulate pond pump
• Check sensor position (page 4 & 6)
• Refill pond
• Clean screen with citric acid, if heavily soiled, use hydrochloric acid (30%)
• Check motor by connecting it to a regular wall outlet (220V)
• Let motor cool down (ca. 60 minutes)
• Replace relay
• Plug should be in socket "DRUMFILTER MOTOR"
• Check cleaning pump by connecting it to a regular wall outlet (220V)
• Plug should be in socket "CLEANING PUMP"
• Replace relay
AQUAFORTE PRIME DRUMFILTERS VERSION 1.01 01/2024