Set level control
Sensors must be located in dirty water chamber. NOTE: The pins of the sensors must first be shortened for pump-fed use! The long pin must be shortened 50mm and the short pin must be
shortened 30mm. See picture 5.
Picture 6
1. Water level with running pump after rinse
2. Start rinsing. Dry run protection after set "DRY RUN TIME")
30mm
50mm
GUTTER FLUSH
The drum filters are equipped with an internal flushing pump and a function to rinse the gutter clean. This gutter flush can be used in 2 ways:
1. Continuous: open the tap (partially or completely) to allow water to also spray to the gutter during flushing. This way, the gutter is also flushed clean with each flush.
CAUTION: Continuously opening this tap causes more water loss.
2. Incidental/manual: If there is dirt remaining in the gutter that will not go away with normal flushing, open the tap and press the MANUAL CLEANING button on the controller to manually
flush the gutter clean. After flushing, close the valve again to avoid additional water loss.
CLOSED
6
AQUAFORTE PRIME DRUMFILTERS VERSION 1.01 01/2024
Picture 5
OPEN
Picture 6
2
100mm
1