CONTROLLER
The controller is not waterproof, please keep it out of the water! Place it under a cover, protected from rain and wind.
Manual cleaning:
Press and hold this
button for manual
cleaning
Socket
drumfilter motor
Configuration
Dip switch
1 on: gravity
1 off: pump fed
2 on: sensor 2-pens
2 off: float switch
(3 & 4 are not in use)
dip switch
on
off
1 2 3 4
Socket
Socket
cleaning pump
circulation pump
Potentiometers
Power switch
(Emergency switch)
Socket sensor
DELAY TIME : set time when pond pump switches off
(delay to power off) 2-25 seconds
DRY RUN TIME : set the time that the pond pump remains off
(delay to power on) 10-70 seconds
CLEAN TIME : set rinse time 10-70 seconds
WATER THRESH : set sensor sensitivity 0-100%
AQUAFORTE PRIME DRUMFILTERS VERSION 1.01 01/2024
3