The light is switched off in spite of the presence
of persons and in spite of insufficient brightness;
the LED is off.
Cause: Detection problem: the surface to be moni-
tored is outside the detecting range; obstacles are
in the way.
If necessary, use an additional extension unit in
order to enlarge the detecting range (Enlarging the
detecting range).
The light is switched on without any movements.
Cause: sources of interference inside the detecting
range.
Restrict the detecting range or readjust the sen-
sitivity.
The light switches off briefly and then on again
immediately; toggling effect.
Cause 1: sources of interference inside the detecting
range.
Restrict the detecting range or readjust the sen-
sitivity.
Cause 2: Wiring error: main units connected in parallel
to enlarge detecting range.
Use extension units (Enlarging the detection
range).
NL
Verlichting schakelt uit, ofschoon personen aan-
wezig zijn en het licht niet toereikend is, LED is
uit.
Oorzaak: Detectieprobleem, het te bewaken oppervlak
ligt niet binnen het detectiegebied, objecten vormen
een obstakel.
Eventueel extra impulsgever toepassen, om de-
tectiegebied te verruimen (zie Detectiegebied ver-
groten).
Verlichting schakelt zonder herkenbare beweging in.
Oorzaak: Storingsbronnen in het detectiegebied.
Detectiebereik inperken en/of gevoeligheid instellen.
Verlichting schakelt kort uit en onmiddellijk weer
in, lichtschommeling.
Oorzaak 1: Storingsbronnen in het detectiegebied.
Detectiebereik inperken en/of gevoeligheid instellen.
Oorzaak 2: Installatiefout, hoofdtoestellen parallel ge-
schakeld om detectiegebied te vergroten.
Impulsgevers toepassen (Detectiebereik vergroten).