6.2 Help in case of trouble
In spite of insufficient brightness, the device does
not switch on the light in the case of movements.
The LED is lit up in the case of detection.
Movements detected by an extension are not indi-
cated by the LED of the main unit.
Cause: brightness threshold at main unit not high
enough.
Turn the lux potentiometer in the direction of the
symbol.
In spite of insufficient brightness, the device does
not switch on the light in the case of movements,
the LED is off.
Movements detected by an extension are not indi-
cated by the LED of the main unit.
Cause 1: sensitivity level not high enough.
Turn the sens potentiometer in the max direction.
Cause 2: detection range too narrow.
Use additional extension units.
Cause 3: detecting range is restricted by the mask.
Remove the mask (5) or modify.
NL
6.2 Hulp in geval van problemen
Verlichting schakelt ondanks te geringe helder-
heid bij beweging niet in. Bij detectie brandt de
LED.
Detecties door een impulsgever worden door de LED
van het hoofdtoestel niet gesignaleerd.
Oorzaak: De op het hoofdtoestel ingestelde helder-
heidswaarde is te laag
Potentiometer lux richting
Verlichting schakelt ondanks te geringe helder-
heid bij beweging niet in, LED is uit.
Detecties door een impulsgever worden door de LED
van het hoofdtoestel niet gesignaleerd.
Oorzaak 1: Ingestelde gevoeligheid is te laag
Potentiometer sens richting max draaien.
Oorzaak 2: Detectiegebied te klein.
Extra impulsgevers toepassen
Oorzaak 3: Detectiegebied is met kapje ingeperkt.
Kapje (5) verwijderen of aanpassen.
draaien.
47