Instruction Manual
OPERATION MODES
Ventilation Mode. The fan operates in exhaust or supply mode at a fixed speed. When two
connected fans are synchronized, one operates in supply mode while the other operates in
exhaust mode.
Regeneration Mode. The fan operates in two cycles of 75 seconds each to provide heat and
humidity regulation.
Interval 1 The warm, contaminated air is extracted from the room and passes through the
ceramic core, gradually absorbing heat and moisture. After 75 seconds, the fan switches to
supply mode.
Interval 2 The fresh and cold outdoor air passes through the heat exchanger and absorbs the
accumulated heat. After 75 seconds, when the ceramic core becomes cold, the fan switches to
exhaust mode.
Exhaust mode
CAUTION!
for the user and the installer

INSTALLATION AND SET-UP

Read the user manual before installation.
To prevent dust accumulation in the room, the fan should not be
installed where the air duct can be blocked by blinds, curtains, etc.
Additionally, curtains can obstruct normal airflow in the room, which
may affect the fan's operation.
Supply mode
87
Exhaust
mode
75 S
Supply
mode