Pos: 92 /Alle Produkte/Überschriften/H1 Installation @ 7\mod_1196624877149_121.doc @ 41391 @
4.

Installation

Pos: 93 /Filter/SwimSkim CWS/INS_Montieren und Aufstellen SwimSkim CWS @ 8\mod_1222094823335_121.doc @ 53205 @
Assesmbly of the SwimSkim CWS (Figure B, C)
1. Plug the handle (4) on the filter basket (8).
2. Fit the float switch (2):
Start by inserting the bottom engagement hook (9) in the opening of the pump chamber provided
for this purpose.
Then press the float switch down while swinging it against the pump chamber, until the upper
engagement hook (10) audibly engages.
3. Tighten the flow-out nozzle (3) at the pump on the underside of the pump chamber.
4. Align the flow-out nozzle (3) with the flat sealing ring (14) opposite to the skimmer flap (13).
The flow-out nozzle is correctly aligned when the arrows (11) on the underside of the unit and on
the flow-out nozzle point to one another.
Note: The blowback generated by the flow-out nozzle firmly holds the SwimSkim CWS at the
securing cord or at the securing cords (D) once fastened to the ground stakes.
5. Adjusting the flow-out nozzle (3).
With swirl-up function: Turn the valve (12) such that the water flows out downward to swirl up the
sludge from the bottom of the pond.
Without swirl-up function: Turn the valve (12) such that the water flows out sideways. The sludge
on the bottom of the pond is not swirled up.
6. Inserting the foam filter (7):
If necessary, the foam filter (7) can be used to filter out fine-grain soiling (e.g. pollen).
Installing the SwimSkim CWS (Figure D)
1. Place the SwimSkim CWS into the pond.
2. Fix the SwimSkim CWS in the pond:
Fasten at the pond edge: Fasten one securing cord each from the scope of delivery at the eyelets
of two float switches (2). Fix the securing cords at the pond edge using the ground stakes (6) such
that the SwimSkim CWS is in its desired position.
Fasten at the bottom of the pond: Fasten one securing cord each from the scope of delivery at the
two eyelets at the unit underside (1). Fix the securing cords to the bottom of the pond, e.g. using
rocks, such that the SwimSkim CWS is in its desired position.
Note: Only put the SwimSkim CWS into use when it is firmly fixed in the pond.
Pos: 94 /Alle Produkte/Dummy_module/Abstand 18 pt @ 6\mod_1196355593257_0.doc @ 41089 @
Pos: 95 /Alle Produkte/Überschriften/H1 Inbetriebnahme @ 7\mod_1196625111244_121.doc @ 41417 @
5.

Start-up

Pos: 96 /Filter/SwimSkim CWS/INB Inbetriebnahme SwimSkim CWS @ 8\mod_1221649414453_121.doc @ 52913 @
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Disconnect the power plug (Figure E, 15) prior to reaching into the water and
commencing work.
Follow the safety information!
The pump in the SwimSkim CWS switches on automatically when the power connection is established.
Switching on (Fig. E): Plug the power plug (15) into the socket.
Switching off (Fig. E): Disconnect the power plug (15).
The pump is equipped with a dry run protection. If no water is primed, the pump switches off ten times
for approx. 3 seconds each. Following this the pump shuts down.
Switching on the pump again:
Pull the power plug (15) and reinsert into the socket (reset function).
Pos: 97 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @
- GB -