RF BF 74 SW868/SW915/SW917/SW922-NET
Montage- und Anschlussanleitung / Funk-Befehlsgeräte
Mounting and wiring instructions / Wireless command devices
Instructions de montage et de câblage / Organes de commande sans fil
Istruzioni di montaggio e collegamento / Dispositivi di comando wireless
Instruções de montagem e instalação / Dispositivos de comando sem fio
English
Penetration of radio signals:
Material
wood, gypsum, glas uncoated
brick stone, press boards
armoured concrete
metal, aluminium lamination, water
Typical ranges:
Location
in free field (SW868/915/917)
in free field (SW922)
indoors (SW868/915/917)
indoors (SW922)
Field strength meter for range test:
Transmitter
Device
SW868
swView 868 MHz
SW915
swView 915 MHz
SW917/SW922
Radio operation
The transmission of a switching command from the transmitter to
the receiver takes about 80 to 100 ms, based on the sWave® data
transmission. The switching signal from a transmitter may not be gen-
erated at a shorter interval, otherwise the signal will be suppressed.
The receiver must conform to the sWave.NET® protocol of the steute
modules. To avoid too fast actuation, there is, by default, a delay time
of 1 s when processing one switching command from transmitter to
receiver (if the radio interface is unoccupied and there are no repeat
telegrams). The preset delay time of 1 s can be adjusted from min.
0.5 s to max. 31 s (configurable on the Sensor Bridge interface under:
»Groups«, »Timing«).
Allocation of locations and radio frequencies:
Device type Radio frequency
SW868
868.3 MHz
SW915
915.0 MHz
SW917
917.0 MHz
SW922
916.5 MHz
Penetration
90...100 %
65...95 %
10...90 %
0...10 %
Wireless range (approx.)
450 m
150 m
40 m
20 m
Material No.
1190393
1221794
on request
Location
According to
EU
2014/53/EU (RED)
USA
FCC
Canada
IC
Mexico
IFT
Brazil
ANATEL
Japan
ARIB STD-T108
Battery
The battery voltage is displayed on the Sensor Bridge interface under
»Sensors & Actors« in percent. In addition, the battery voltage is
displayed in the logs in mV.
When the battery voltage acc. to the radio protocol drops below approx.
<3200 mV (at 20°C, load approx. 20 mA), it may be assumed that the
battery is empty. Attention: The open circuit voltage measurement
does not provide reliable information! In order to ensure reliable func-
tioning, the battery must be replaced.
Variants with battery included in delivery:
Name
RF BF 74 RT SW868 NET
RF BF 74 RS SW868 NET
RF BF 74 RT/RT SW868 NET
RF BF 74 RT/RT/RS GE SW868-NET
The delivery includes one ½-AA lithium battery SL-750/3.6 V/1.1 Ah.
To replace the battery: see section »Battery replacement«.
Variants without battery included in delivery:
Name
RF BF 74-2 SW868 w/o BATT
RF BF 74 RT SW915-W/O-NET
RF BF 74 RT/RT SW915-W/O-NET
RF BF 74 RT SW917-W/O-NET
To insert the battery: see section »Battery replacement«.
Suitable battery: see Spare parts.
Spare parts:
Name
Lithium battery SL-750/3.6 V/1.1 Ah
Cover for battery compartment 108 type ½-AA
Attachable bracket (optional) holds battery securely in place to with-
stand impacts and vibrations.
Maintenance and cleaning
.steute recommends routine maintenance as follows:
1. Remove all dirt particles: Clean enclosure on the outside only.
Clean device in accordance with IP protection class. Clean with
a soft cloth and water or a mild detergent. Do not clean using com-
pressed air.
2. Replace damaged parts.
3. Test the function.
Disposal
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately. Dispose of possibly contained
batteries correctly.
3 / 16