4. Scope of delivery
T.I.P. external pond filter:
MTS 10000 UV 11 W: filter container, Bioballs, Wet-and-Dry unit, back wash, UVC emitter 11 Watt, 1
sponge, 3 m spiral hose (ø 25 mm), 2 m spiral hose (ø 32 mm), pump PKH 2600, operating instruction.
MTS 20000 UV 18 W: filter container, Bioballs, Wet-and-Dry unit, back wash, UVC emitter 11 Watt, 1
sponge, 3 m spiral hose (ø 25 mm), 2 m spiral hose (ø 50 mm), pump PKH 4000, operating instruction.
Check the device for transport damage and complete delivery. If there is damage the retailer must be notified
without delay, at the latest however, within 8 days of the purchase date.
If possible, dispose the packaging until the end of the warranty period. Dispose of packaging materials in an
environmentally friendly manner.
5. Installation
Do not use excessive force that can cause damage when tightening threaded unions.
The numbers and other information cited below in parentheses are based on this illustration.
5.1.
Mounting
Install the UV-C sterilizer in the compartment under the case, fastening it with the relevant fittings and rubber
seal as illustrated in appendix (A, B, C)
 Install the drain valve (4) with the relevant fitting (3) and seal (5) as illustrated in appendix (C)
 Install the outlet fitting (8) with the relevant fitting (7) and seal (6) as illustrated in appendix (C)
 Position the sponge (3) as illustrated in appendix (D)
 Place the biological filtering material (Bioballs) (2) in the relevant compartment as illustrated in appendix
(D)
 Position the wet-and-dry perforated screen (1) as illustrated in appendix (D)
 Assemble the cover with the 2 pipes (MTS 10000, 6) / 8 pipes (MTS 20000, 6) and sponge retaining grid
(5). (E)
 INLET connection: connect the pump (9) with the hose-end fitting and 3m spiral hose (10) to the UV-C
sterilizer's inlet as illustrated in appendix (F). When necessary, use a clamp to make the connection more
secure.
 Suggestion for MTS 10000: Adjust the hose connection ports to the size of the hose that is used; to do
this, use a standard household saw to cut off the smaller hose diameter that is not required on the
connection ports.
 OUTLET connection: connect the 2m spiral hose (11) to the outlet fitting as illustrated in appendix (F).
When necessary, use a clamp to make the connection more secure.
 Determine which point near the pond makes the best location, bearing in mind the lengths of the pipes
supplied.
 Switch on the pump, check to see that the filter fills and that water comes out of the outlet correctly. It is
not a problem if the sponge rises since the grid located on the cover will keep it in the correct working
position.
 Close the cover.
 Switch on the UV-C sterilizer and check that the lamp is working through the opaque glass screen.
Warning
 The filter must always be positioned above the pond's water level.
 Place the filter horizontally (to prevent water overflowing).
 To encourage water to leave the filter, the outlet pipe must never be higher than the level of the
connection hole it comes from.
 If there is any overflowing, make sure that the wet-and-dry screen (D 1) and the filter in the discharge
chamber are clean.
 If there is any overflowing, make sure that the wet-and-dry screen and the filter in the discharge chamber
are clean.
5.2.
Setting up at the garden pond
Place the filter above the water level (filter outflow at least 15 cm above the water surface) and ensure that
the filter is at least 2 meters away from your pond. The container should be placed horizontally on a solid
substrate (stone slab). Ensure, that it cannot fall into the water and that the installation area of the filter
cannot be flooded.