Herunterladen Diese Seite drucken

Balluff BCS Q40BBAA-PSICFHC- Serie Betriebsanleitung Seite 24

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BCS Q40BBAA-PSICFHC-...
Capacitive Proximity Switches
3
Construction and function
Series BCS Q40BBAA-PSICFHC-... sensors operate using
the capacitive Smart-Level measuring principle and are
used for level detection of conductive media.
They detect levels even when there is product build-up
and automatically masks glass and plastic walls of up to
0.5 to 6 mm thickness.
The sensors can be used for many standard applications
ex factory without needing calibration.
Product characteristics:
Operating modes: Standard I/O mode (SIO), IO-Link
mode
Settable switchpoint (Teach-in), configurable via IO-Link
Displays Switching State and Ready
Protection from short circuit, voltage reversal, and
polarity reversal
Approvals: CE, cULus, EAC
This sensor provides an IO-Link communication interface
which enables direct access to process and diagnostic
data or for configuration of the sensor. An IO-Link master
is required for communication over the IO-Link interface.
Without an IO-Link master the sensor is immediately
usable with a standard switching output in the SIO Mode
(Standard I/O Mode).
The switching output is factory set as a PNP
normally open.
6
english
Sensor construction
1 Active surface
2 Switching state indicator (yellow LED)
3 Sensor status indicator (green LED)
4 Mounting holes
5 Connection cable
Fig. 3-1:
Sensor construction