Herunterladen Diese Seite drucken

Siko MA355 Benutzerinformation Seite 9

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

To enter into the programming mode
Press key
for at least 3 sec.
The name of the parameter is displayed in the first
line. The third line indicates the value of the cur-
rent parameter.
To leave programming mode:
Automatically, if no key has been pressed during
approx. 30 s, or press key
parameter list is reached.
To scroll parameter information:
Use key
To change parameters:
Use keys
and
To store the modified parameters:
press key
9. Parameter Description
At the end of this user information brochure you
will find a detailed parameter list showing all
programmable parameters and offering space for
customer-specific programming values.
Display
Designation/ Description
"Display"
-APU- (X)
Resolution
Resolution in increments per
revolution
Value range: 0 ... 59999
-STr- (X)
Increments
Encoder increments
Value range: 0 ... 59999
-DP- (X)
Positions after the comma
Value range: "0." ... "0.000"
-DrEh- (X) Counting direction
Counting direction related to clo-
ckwise or anti-clockwise direction.
Selectable values: "I", "E"
-Ind- (X)
Index type
Selectable values: "0", "I"
-rFS- (X)
Referencing type
Referencing via referencing switch
or conjunction only
Selectable values: "Hand", "Auto"
-rEF- (X)
Reference value
Input of display va-
lue for referencing
-rEL-F
Incremental measurement enable
Selectable values: "AUS", "Ein"
-rEF-F
Reference value input enable
Selectable values: "AUS", "Ein"
MA355-S
Datum 18.04.2006
until the end of the
Art.Nr. 82850
Display
Designation/ Description
"Display"
-SEt-F
Reset via key
Selectable values: "AUS", "Ein"
-Cntr-
Control
Not implemented at present
-CodE-
Code
Set device to specified parameters
Attention! (X) = 1, 2 or 3 (channel number). The-
se parameters can be parameterized separately for
each channel.
10. Input Mode
Attention! Before starting with the programming of
the below mentioned functions, first select correct
channel via
-key.
Incremental measurement function
By pressing the
key (hold down) with sub-
sequent pressing of the
measurement mode is activated. A blinking dot
in the first digit indicates that the display is
being operated in the incremental measurement
mode.
Switching off by repeated pressing of the
(hold down) with subsequent pressing of the
key. The absolute measuring value is displayed
again.
Precondition: Menu point 'Incremental measure-
ment enable' (-rEL-F) in programming mode must
be programmed to "Ein", but unit must not be left
in programming mode.
Direct alteration or reference value
By pressing the
key (hold down) with subse-
quent pressing of the
input is activated.
The new reference value can be entered by using
the arrow keys.
By pressing the
key the entered value is taken
over and saved.
Precondition: In programming mode menu point
'reference value input enable' (-rEF-F) must be
programmed to "Ein", but unit must not be left in
programming mode.
enable
key the incremental
key
key the reference value
Änd. Stand 161/06
9

Werbung

loading