Herunterladen Diese Seite drucken

Strong line XT80310 Original Bedienungsanleitung Seite 25

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• We recommend that you clean the equipment im-
mediately after you use it.
• Clean the equipment regularly with a damp cloth
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the plastic
parts in the equipment. Ensure that no water can
get into the interior of the equipment.
• You must disconnect the hose and any spraying
tools from the compressor before cleaning. Do not
clean the compressor with water, solvents or the
like.
• Clean the fan with compressed air at low pressure.
10.2 Maintenance work on the pressure vessel
(fig. 3)
Important
To ensure a long service life of the pressure vessel
(2), drain off the condensed water by opening the
drain plug (1) each time after using.
10.2.1 Draining condensed water
• First release the vessel pressure (see 10.7.1).
• Open the drain plug by turning counter-clockwise
(looking at the plug from the bottom of the com-
pressor) so that all the condensed water can run
out of the pressure vessel.
• Then close the drain plug again (turn it clockwise).
10.2.2 Checking the pressure vessel
• Check the pressure vessel for signs of rust and
damage each time before using.
• Do not use the compressor with a damaged or
rusty pressure vessel.
• If you discover any damage, then please contact
the customer service workshop.
10.3 Safety valve (fig. 2/14)
The safety valve (14) has been set for the highest per-
mitted pressure of the pressure vessel. It is not permit-
ted to adjust the safety valve or remove the connec-
tion lock (14.2) between the exhaust nut (14.1) and its
cap (14.3).
Actuate the safety valve every 30 operating hours
but at least 3 times a year, to ensure that it works
when required. Turn the perforated exhaust nut (14.1)
counterclockwise to open it and use your hands to
pull the valve rod outwards over the perforated ex-
haust nut (14.1) to open the safety valve outlet. Now,
the valve audibly releases air. Then, tighten the ex-
haust nut clockwise again.
10.4 Checking the oil level at regular intervals
(fig. 11)
• Place the compressor on a level and straight sur-
face.
• The oil level must be between the MAX and MIN
marks on the oil level sight glass (12).
10.5 Changing the oil (fig. 11)
The original oil filling must be changed after 10 hours
in operation. Thereafter the oil must be drained and
replaced with new oil after every 50 hours in opera-
tion. We recommend SAE 15W 40 or equivalent.
10.5.1 Draining oil
• Switch off the engine and pull the mains plug out
of the socket.
• After releasing any air pressure you can unscrew
the oil drain plug (13) from the compressor pump.
• To prevent the oil from running out in an uncon-
trolled manner, hold a small metal chute under
the opening and collect the oil in a vessel. If the
oil does not drain out completely, we recommend
tilting the compressor slightly.
• When the oil has drained out, re-fit the oil drain plug
(13).
• Dispose of the old oil at a drop-off point for old oil.
10.5.2 Filling in oil
• To fill in the correct quantity of oil, make sure that
the compressor stands on an even surface.
• Fill new oil through the oil filler opening (11) until it
comes up to the maximum level. This is marked with a
red dot on the oil level sight glass (12) (fig. 11 pos. 12.1).
Do not exceed the maximum filling quantity. Over-
filling the equipment may result in damage.
• Reinsert the oil closing plug (11) into the oil filler
opening.
10.6 Cleaning the intake filter (fig. 13, 14)
The intake filter prevents dust and dirt being drawn
in. It is essential to clean this filter after at least every
300 hours in service. A clogged intake filter will de-
crease the compressor's performance dramatically.
• Remove the intake filter by opening the crosshead
screw (G).
• Then pull off the filter cover (J). Now you can re-
move the air filter (L) and the filter housing (K).
• Carefully tap out the air filter, filter cover and filter
housing.
• Blow out these parts with compressed air (approx.
3 bar) and reinstall in reverse order.
10.7 Storage
m Caution
Pull out the mains plug and ventilate the equip-
ment and all connected pneumatic tools. Switch
off the compressor and make sure that it is se-
cured in such a way that it cannot be started up
again by any unauthorized person.
m Important
Store the compressor only in a dry location
which is not accessible to unauthorized persons.
Always store upright, never tilted!
GB | 25

Werbung

loading

Diese Anleitung auch für:

3906136987