Operation and trouble shooting
For the device to function correctly it must be connected to a power supply and the measurement pipe must be completely full.
In the junction box are two LEDs which indicating the operating status and/or faults by means of three patterns:
- White LED flashes or is illuminated: flow indication analogous to the output pulse
- Red LED flashes or is illuminated: flow negative or against flow direction (arrow direction on housing)
- White and red LED flash or are illuminated simultaneously: flow above specified level
Problem
No output volume pulses
Unstable measurements
AMFLO
MAG Basic
®
Possible causes
Has the device been connected to the power supply?
Does the voltage correspond to the specifications?
Is the pipework partially filled or empty?
Is there flow?
Is the flow velocity or the flow rate outside the specification?
Is the flow rate below the cutoff value?
Has the device been mounted in the right direction?
Are the electrodes dirty?
Is the electrical wiring correct?
Is the actual flow rate stable?
Is the flow velocity or flow rate outside the specification?
Is the device properly grounded?
Are the electrodes dirty?
Is the pipework only partially full?
Are gas bubbles in the pipework?