Herunterladen Diese Seite drucken

INTEGRA Metering AMFLO MAG Basic Montage- Und Bedienungsanleitung Seite 12

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Avoid installing the flow sensor
in long pipes without supports.
Avoid vibrations.
Partially filled pipes will cause
considerable measuring errors
and must be avoided.
Avoid faulty readings resulting
from installation close to valves,
elbows, pumps etc..
Large initial gaps between pipe
work and flow sensor can result
in large torsional and bending
strains on the device when tigh-
tening the nuts.
Air bubbles can contact electro-
des and disturbe measuring.
12
In installations with long pipes
connecting to the device, an-
tivibration joints should be used.
In operation, the pipe must be
completely full at all times.
3 x
To get precise readings, keep to
inlet pipe section of 3 × ND and
outlet section of 2 × ND.
2 x
The gaps provided for the gas-
kets must be as small as pos-
sible so that, when tightening
the nuts, the device is not under
strain.
-45
+45
Mounting angle with sensor
neck upwards +/- 45°.
AMFLO
MAG Basic
®

Werbung

loading