Electrical installation
Power supply
24 VDC ±10 % (max. current 150 mA).
The voltage deviations of ±10% must not be exceeded.
Wiring
Use a connecting cable with a cross section of 0.25 – 1.5 mm
necessary.
Maximum cable length 10 m according to the EMC Directive.
LED:
Status
Pulse
1
Status
2
Common
Pulse
3
+24V DC
4
5
GND
Pulse output (2/3):
Mode: passive (solid state relais)
Max. current/max. voltage: 50 mA, 48 V
Max. output frequency: 200 Hz
Nominal diameter DN
Pulse value
AMFLO
MAG Basic
®
1
2
3
4
5
mm
inches
L
. Strip 8 mm of the outer insulation at the ends or use end ferrules if
2
Flow
125
150
5
6
1
2
200
250
8
10
2
5
13

Werbung