Voltage DC
Range
2 V
20 V
200 V
600 V
Input impedance: 10 MOhm,
Voltage AC (50...400 Hz)
Range
2000 mV
20 V
200 V
600 V
Input impedance: 10 MOhm,
Battery-Test
Range
Resolution Accuracy
1,5 V
10 mV
9 V
10 mV
Current DC
Range
200 mA
15,00 A*
*10 A contionous, 15 A for max. 30 s with 5 min cool down time
Overload protection:
Fuse (mA) :
Fuse (A) :
Resolution
Accuracy
1 mV
10 mV
± (0,8% v.M.+3D)
100 mV
1 V
Resolution
Accuracy
1 mV
10 mV
± (1,5% v.M.+5D)
100 mV
1 V
± (1,5% v.M.+3D) 30mA (±20%)
Resolution
Accuracy
0,1 mA
± (1,5% v.M.+5 D)
0,01 A
± (2% v.M.+5 D)
Overload protection
600 Veff
Overload protection
600 Veff
Test current
10mA (±20%)
Burden voltage
5 mV/mA
0,04 V/A
F200mA 250V Ceramic 5x20mm
F10A 250V Ceramic 5x20mm
Overload protection
250 Veff