Herunterladen Diese Seite drucken

REHM MIG - COOL CART 100 Betriebsanleitung Seite 21

Wasserkühlgerät

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.
Error message
Error message
Screen message "Err H2O" shown on the digital display of the MEGAPULS 250
Cause:
Insufficient throughput of coolant
8.
Technical data of the MIG - COOL CART 100
Mains voltage
Power consumption
Cooling capacity max. (Air 20°C, 2.3 lpm)
Feed rate maximum
Pump pressure maximum
Coolant capacity
Protection class
Dimensions (L x W x H)
Weight when empty (without coolant)
9.
Correct disposal
Only applies to countries in the EU.
Do not dispose of electrical tools in the household rubbish.
The European Directive 2002/96/EC regarding the disposal of electronic and
electrical goods and the implementation of such in national law means that
used electrical tools must be collected separately and sent for
environmentally-friendly recycling.
Solution:
Switch off the system immediately.
Check the connections of the water-cooled
torch.
Check the water level in the tank.
400 VAC
0.3 A
1000 W
2.1 lpm
0.6 MPa (6 bar)
5.0 litres
IP 23
1110 x 600 x 880mm
65 kg
GB