7.
Error message
Error message
Screen message "Err H2O" shown on the digital display of the MEGAPULS 250
Cause:
Insufficient throughput of coolant
8.
Technical data of the MIG - COOL CART 100
Mains voltage
Power consumption
Cooling capacity max. (Air 20°C, 2.3 lpm)
Feed rate maximum
Pump pressure maximum
Coolant capacity
Protection class
Dimensions (L x W x H)
Weight when empty (without coolant)
9.
Correct disposal
Only applies to countries in the EU.
Do not dispose of electrical tools in the household rubbish.
The European Directive 2002/96/EC regarding the disposal of electronic and
electrical goods and the implementation of such in national law means that
used electrical tools must be collected separately and sent for
environmentally-friendly recycling.
Solution:
Switch off the system immediately.
Check the connections of the water-cooled
torch.
Check the water level in the tank.
400 VAC
0.3 A
1000 W
2.1 lpm
0.6 MPa (6 bar)
5.0 litres
IP 23
1110 x 600 x 880mm
65 kg
GB
9