Comfort Electronics K4,
Operation, Maintenance, Troubleshooting
32
Motor adjustment
The motor should be adjusted
after the shower panel has
been put into operation to
adapt it to local home
conditions. These depend on
the type of heating used and
the available warm water
temperature. Attention:
These specifications can
change later when a heating
system is installed or
modified, or the water
temperature is changed.
...and it is as simple as
this:
The shower panel must be in
"stand-by" mode (display has
background lighting, no func-
tions are active). The hand
shower is activated automati-
cally during motor adjustment.
First press the >42° (
)
button as well as the Body
shower (
) button until
tCH is displayed.
Now press the Mode (
button: Motor adjustment now
runs automatically. It takes
about 7 minutes.
The letter C is displayed
when motor adjustment has
finished.
Pressing the Mode (
)
button saves the motor
adjustment.
Light on/off
The shower lighting can be
switched on and off with the
Light (
) button.
Attention:
Water emerges: Therefore
check the position of the hand
shower!
Pressing the >42° (
)
button stops motor adjustment
prematurely (the last valid
factory setting curve is then
applicable).
The lighting switches off
automatically after the
shower. Factory setting:
2 minutes; individually
adjustable 1 – 50 min.
)

Werbung