Fittings / Technical Data / Safety Instructions
Technical Data
Minimum flow pressure
Operating pressure
Recommended operating pressure
Test pressure
Hot water temperature
Temperature scale
Safety stop
Flow capacity at 3 bar
Hand shower (1)
Body showers, 6 jets (2)
Overhead shower
Overhead shower + body showers
Overhead shower + hand shower
Hand shower + body showers (3)
24
Flow heater:
The Shower Panel cannot be used together with hydrauli-
cally, electronically or thermostatically driven flow heaters.
Pressure differences:
The pressures of the cold and hot water connections must be
balanced.
Safety instructions for connecting the DP Prestige
EL 40:
You only require a socket for the electrical installation of the
Shower panel. An external transformer is supplied to
operate the lighting.
Electrical socket installation must only be performed by a
qualified electrician. The complete power supply runs via a
230 V/50 Hz AC connection and must be protected by a 2-
pole residual current operated circuit breaker with 30 mA
fault current.
The relevant national regulations in the applicable version
must be observed during electrical installation. Installation
and in spection tasks must be performed by authorized
electricians. All work on the Shower Paneel must be
performed with the power disconnected.
The external transformer performance is 50 VA. A wiring
conduit with a diameter of at least 25 mm must be provided
to install the power supply cable. The transformer must be
installed in the dry area (protection zone 3). The cable
provided allows the transformer to be installed max. approx.
7 m from the Shower Paneel. The transformer must be
accessible at all times. A damaged connection cable cannot
be replaced, and the transformer must not be operated in
this case.
1.5 bar
max. 10 bar
2 – 5 bar
16 bar
max. 70°C
20 – 60°C
38°C
15 l/min
22 l/min
14 l/min
28 l/min
23 l/min
29 l/min
From • the function is guaranteed.