Herunterladen Diese Seite drucken

King gates ROLLS-Serie Anweisungen Und Warnungen Zur Installation Und Benutzung Seite 38

Elektromechanischer stellantrieb fuer sektionaltore und schwingtore
Vorschau ausblenden Andere Handbücher für ROLLS-Serie:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 104
9 - RESET PROCEDURE
Reset procedure deletes door travel parameters (par. 6) and all
advanced functions (par. 11). It can be performed in case of
programming mistakes and it brings the STAR GDO control board
back to factory settings.
m
This reset doesn't affect memorized radio transmitters
(see par. 5 for radio trasmitters management).
1. PRESS THE START BUTTON FOR 8 SECONDS: All LED flash
2. RELEASE THE START BUTTON: All LED continue to flash
3. PRESS THE START BUTTON FOR 3 SECONDS: All LED light up
in series
4. RESET IS NOW COMPLETED: The red "ERROR" LED lights
flashes 3 times continuosly
5. NEW PROGRAMMING OF THE AUTOMATION'S MOVEMENTS
IS REQUIRED
10 - DEVICES CONNECTABLE TO THE
CONTROL UNIT
10.6
10.1 - 10.2
10.3
10.2
10.5
10.3
The control unit is prearranged for interfacing with different
devices dedicated to system control, system safety and other
additional functions. Below is a list of their connections and
corresponding functions.
- 36 - ENGLISH
10.4
L
N
10.1 - WARNING LIGHT
TERMINALS: 1-2
The warning light is an accessory used for signaling any
movement of the gate leaf.
Connected lamps: 24V 15W maximum power.
10.2 - AUX OUTPUT CONTACT
TERMINALS: 1-2 o 4-8
Default setting: 24Vdc output for inductive loads (relay) not active
at the factory.
See paragraph 13 to activate the AUX output. By default, the AUX
output is bistable and is associated with the remote control key
memorized for this function.
10.3 - SAFETY DEVICES
TERMINALS: 3 (S2 Photo) and 9 (S1 Edge)
The control unit has two safety inputs available for voltage free
(dry contact) connection(s).
"S2 Photo" CLOSING or OPENING/CLOSING PHASE SAFETY
DEVICES
Terminal 3 allows the connection of safety devices active during
the closing and opening phases. This input is normally closed
(NC). For infrared photocells and safety edges with micro-switch
contact. The factory wire bridge connected to S2 Photo must be
removed when using this input.
These devices intervene during the gate's closing and opening
phase according to DIP switch 4 (see par. 4.1).
In particular:
DIP4 set to ON:
-
during the closing phase, they stop the movement and reopen
when disengaged
-
during the opening phase they stop the movement and
reopen when disengaged
-
with the opened door they lock closing commands
-
with the closed door they lock the opening commands.
DIP4 set to OFF:
-
during the closing phase they lock the movement and re-open
the door fully when released
-
during the opening phase they do not intervene
-
with the opened door they lock closing commands
-
with the door closed they allow opening
m
When multiple devices are connected on this contact,
they must be connected in series.
m
If more photocell pairs are connected, RX and TX units
of the safety set should be cross installed.

Werbung

loading

Diese Anleitung auch für:

Rolls700Rolls1200Rolls 700 ngRolls 1200 ng