INSTALLATIoN
electrical connection
11.2 Safety extra low voltage
Xd04
Terminal, external safety extra low voltage
T(MK)
Mixer circuit temperature sensor
(Function available as optional extension)
T(KUE)
Flow sensor, in the case of cooling 
T(WW)
Temperature sensor, DHW (function part of the stand-
ard delivery)
T(Puf)
Temperature sensor, buffer cylinder (function part of
the standard delivery)
11.3 Sensor installation
Note
The temperature sensor needs to be replaced on com-
bined appliance system HSBC 200 L with WPF / WPF cool.
f Use the PTC temperature sensor that was included in
the standard delivery of the heat pump.
36
| HSBC 200 L
BT13
BT20
BT06
Termi-
Safety extra low voltage
nal
XD04
BT06
Temperature sensor, buffer cylinder
BT20
DHW temperature sensor
f Make the electrical connection for the components.
Relevant appliances
Material number
236684
HSBC 200 L
232909
WPF 04
232910
WPF 05
232915
WPF 04 cool
232916
WPF 05 cool
11.3.1 Temperature sensor for area cooling (optional)
Area cooling requires the fitting of a temperature sensor, available
as an accessory.
f Remove the front casing (see chapter "Preparations / Trans-
port and handling / Removing / fitting the front casing").
f Insert the temperature sensor into the sensor well "Sensor
heat pump cooling, optional".