INSTALLATIoN
Installation
10.2.2 HSBC-HKM (optional)
To extend the appliance with a heating circuit with mixer, you can
install pump assembly HSBC-HKM (available as accessory).
- Connection pipes
- Prefitted contact thermostat
- Heating circuit pump
- 3-way mixer with servomotor
- 2 plastic fixing aids
- Operating and installation instructions for the heating circuit
pump
f Remove the EPS profiles from the HSBC side.
f Remove the union nut at the mixed heating return
connection.
f Remove the tee at the mixed heating flow connection of the
buffer cylinder.
32
| HSBC 200 L
1
2
80 Nm +/- 5
14 Nm +/- 0,5
0.5
1 Dummy plug
2 Plastic fixing aid
f Replace the dummy plugs with the enclosed plastic fixing
aids at the mixed heating flow and return connections.
f Fit the pump assembly connection pipes.
f When installing the servomotor, ensure the drive cam is po-
sitioned correctly.
3 x 80 Nm +/- 5
1-2 Nm