HeiTel Digital Video GmbH - Quick Installation Guide CamTel SVR
Pin assignment
terminal block
Labelling/
Pin
description
1
RS-485–
2
RS-485+
⊥
3
4
RS-232 Tx
5
RS-232 Rx
⊥
6
7
Al a/d
8
V out
9
Al in
10
Aux in1
11
Control in 1-2 for
bis
CamTel SVR 4
15
Control in 1-5 for
CamTel SVR 10
⊥
16
⊥
17
18
12V DC +
⊥
19
12V DC
20
R1 [Common]
21
R1 [normally open]
22
R1 [normally
closed]
23
R2 [Common]
24
R2 [normally open]
25
R2 [Normally
closed]
26
Aux in2
⊥
27
28
Control in 3-4 for
bis
CamTel SVR 4
32
Control in 6-10 for
CamTel SVR 10
CamTel SVR
28 / 34 pin terminal block
1
18
Type
Function
Serial (D–)
Use this terminal to connect up to 10 remote control cameras or other
compatible devices (e.g. matrix) with RS-485/RS-422 interfaces.
Serial (D+)
Ground
Common ground for RS-232 interface
Serial TxD
Use this terminal to connect 1 remote control camera or one other
compatible device (e.g. matrix) with RS-232 interface.
Serial RxD
Ground
Common ground for all inputs of type "control input"
Control input
Arm/Disarm input for enabling/disabling dialup to a CamControl receiver
PC, controlled by "Control in", "Al in", and "Motion Detection".
Control input
Control input for manual control of video output (V out)
Control input
Alarm input for dialup with automatic switching of video input 1 (V1 in)
to a CamControl receiver unit.
Control input
Tamper input for dialup with automatic switching of video input 1 (V1 in)
to a CamControl receiver unit.
Control input
Camera control inputs for external contact triggered dialup to a
CamControl receiver unit for video inputs 1 and 2 or 1 to 5.
Ground
Common ground for all inputs of type "control input"
Ground
Common ground for all inputs of type "control input"
Power, +
Connection for 12V DC power supply
Power, Ground
Relay
Device configuration allows you to allocate the following functions to any
relay:
Relay
■
Manual remote control with CamControl LITE, CamControl
Relay
CamControl
functions
■
Relay
Switching to at least one CamControl receiver unit with active online
connection
Relay
■
Error relay
Relay
Control input
Auxiliary input 2: Reserved
Ground
Common ground for all inputs of type "control input"
Control input
Camera control inputs for external contact triggered dialup to a
CamControl receiver unit for video inputs 3 and 4 or 6 to 10.
17
34
CLIENT distinguishing between switch and pushbutton
PRO or
17