Modes Cont.
Autonomous Mode
Autonomous mode means that the device can be installed as a "fit and forget" solution and will send an alert to the Avire
Hub if issues occur. This mode self learns periods of activity and tests the lift depending on the average usual usage of
the lift. If the lift is not active when it usually should be busy the device will assume a fault with the elevator and will run
an automated test of the elevator.
Autonomous mode features 3 sensitivity's, Low – High, Low sensitivity and Medium sensitivity only test the elevator if it
is inactive during usually busy periods, High sensitivity will anticipate busy periods and test the elevator before a busy
period to confirm activity. Note High sensitivity will also test the lift if a perceived fault is present as Medium sensitivity
does.
Triggering Remote Test
Memcom System
To trigger a remote call when wired to a Memcom Emergency Phone System the following steps should be used.
Step
Step 1.
Phone your Memcom number
Step 2.
Step 3.
Step 4.
Step 5.
The remote test is now active, if there is a no motion detected from your remote test, a fault call will be placed back to
the Technical Fault call number specified in your Memcom
Technical Support
If you require any further assistance when programming the HAWK unit, please call our Technical Service Team on 01628
540160
Memco is a brand of Avire
Action
Enter Menu
Trigger Lift Test
Turn Trigger Off
Exit Menu
Emergency Telephone Settings.
+
Avire Ltd
Unit 1, The Switchback
Gardner Road
Maidenhead
Berkshire
SL6 7RJ, UK
Description
Phone number site specific
Default : *1234#
*822#
*821#
*01#
T:
01628 540100
F:
01628 621 947
E:
sales.uk@avire-global.com
W:
www.avire-global.com

Werbung

loading

Diese Anleitung auch für:

Mc-amt00 850mlMc-amt00-100-0-c0-000