Herunterladen Diese Seite drucken

AVIRE Memco Lift HAWK Einbauanleitung Seite 4

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
Installation of Lift Hawk when used with a Memcom
Wiring Diagram
Door Button Wiring Example
Wire lift hawk NC & COM relay in parallel with lift floor buttons, 2 relays are provided for 2 floor call buttons
NOTE: Buttons connections may vary from each manufacturer. The connection provided is a dry contact relay.
Wiring diagram
Settings required for Memcom+
Item
Tech Number
Tech IP 1 Delay
Relay 1 Override
1
2
3
4
5
6
7
R2
R1
Setting
Site Specific / Avire HUB number
1
Open
+
R2
R1
8
9
1 0 1 1
1 2 1 3 1 4
Single relay version Memcom+ only one relay
available and therefore siren cannot be used.
Dual relay version allows for siren to also be
connected.
Guide
Tel Numbers
– Tech No
-– (Tel Number / Avire HUB number)
Delays
– Tech IP
-– ( 1 )
Advanced
– Relay Override
-– 1 (Open)
4

Werbung

loading

Diese Anleitung auch für:

Mc-amt00 850mlMc-amt00-100-0-c0-000