WHAT TO DO IF ...
6
What to do if ...
6.1
... there is no hot water
The tap is fully opened. In this case it could be that the water
heater has not heated the water because there is no power. Check
the MCB/fuse and residual current device in your fuse box.
6.2
... the water fl ow rate is weak
It could be that the jet controller in the tap is contaminated or
scaled up. In this case clean the jet controller or descale it. You
can order the jet controller from us as a replacement part with
part number 279932.
6.3
... the shower is performing poorly
In this situation it could be that the hand shower is scaled up or
contaminated. If so clean the hand shower or descale it. You can
order the hand shower from us as a replacement part with part
number 279482.
6.4
... water is dripping from the tap
When water expands in the water heater expansion water drips
from the tap. This is a normal process.
7
Safety
7.1
Country-specifi c safety information
All required steps up to and including commissioning must be
carried out by a qualifi ed contractor. During this process, these
installation instructions must be observed.
We guarantee trouble-free function and operational reliability
only if original accessories and spare parts intended for this tap
are used.
7.2
Instructions, standards and regulations
Observe all applicable national and local instructions
!
and regulations, e.g. DIN 1988 and EN 806 in
Germany.
8
Appliance description
With the twin-handle wall mounted taps for open-vented (zero
pressure) oversink water heaters, the handles are arranged in
the opposite way to those of mains pressure taps, in accordance
with DIN 44897 T1:
— cold water (blue) left and
— hot water (red) right.
8.1
Standard delivery
The standard delivery is shown in the following diagram. The WBM
tap is shown here as an example.
www.stiebel-eltron.com
9
8
1
Water inlet pipe (chrome-plated brass)
2
Wall connector with butterfl y valve
Extension (30 mm, for water heaters  30 l)
3
4
Hand shower with retainer
5
Spout with perlator
6
Tap handle for hot water
7
Tap body
8
Changeover between spout and hand shower
9
Tap handle for cold water
9
Installation conditions
This tap is intended for a static pressure of up to 0.6 MPa. Install
a pressure reducer upstream from the tap in the water mains if
the static pressure is higher.
10 Installation
»
Thoroughly fl ush the cold water supply line.
»
Debur the pipes if you have reduced them.
»
If necessary adjust the distance between the wall connector and
tap body with water heaters of more than 30 l capacity.
1
2
3
4
7
6
5
WDM | WKM | WBM |