Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connections; Installing The Release Device - Sumo SU2010 Gebrauchsanleitung

Garage door opener
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27

2.6) Electrical connections

The power unit must not be powered during this operation.
!
Thread the power cable and the encoder cable respectively through the central
and the right-hand cable holders. Connect the three-pole power cable (3x2.5)*
to terminals 1 – 2 , keeping the earth wire insulated. Connect the two-wire cable
(2x0.75) to terminals 3 – 4 (encoder).
12

3) Installing the release device

Installing the release device for model SU2000
Unwind the cord (max. L 6.5m) along the wall and thread it through any
eyebolts (not supplied). At a distance of 80mm from the end of the cord,
drill holes and fi x the knob support bracket (42) for releasing from the
ground to the wall (Fig. 13).
Installing the manual release device for model SU2010
Installation of the release system should be divided into two phases.
The fi rst phase can be done on the ground while the second phase can be
done after fi tting the automated system.
Procedure:
Phase 1:
1. Remove a terminal cap from the sheath;
2. Use a Philips screwdriver to unscrew the 3 screws (47-48) of the cover
(3) and remove it;
3. Lower the release lever (5) and block it with the bolt (14);
4. Unscrew the casing of PG7 (22) insert the end of the sheath without the
cap as far as it can go
5. Insert the metal cable into the sheath from the cap side;
6. Tighten the sheath clamp (7) with the relative screws (46).
(Fig. 14).
7. Insert the steel cable into the slot furthest away from the release
lever (5). Block the end of the cable with the relative fi xing clamp making
sure that it doesn't come out even when it is tugged hard (Fig. 15);
4
Tighten the cable holder to prevent the cables from being torn from the terminal board.
fi gs. 12-12a
(Please consult
) Close SUMO by screwing up the 3 screws of the cover
with a Philips screwdriver.
*If the cable is longer than 10m, use a cross-section of 4mm
M
C. C.
1
2
12a
Phase 2:
1. Open the bolt (14) and move the release handle (5) to the initial position;
2. close the cover (3);
3. unwind the sheath (max. L 6.5m) along the wall making sure to keep it
straight so that the metal cable can slide easily inside the sheath;
4. insert the clamp (69) into the metal cable;
5. connect the release knob (43) to the metal cable, remove any excess if
necessary;
6. adjust the fi xing height of the clamp and release (fi g. 16a).
Adjust the position of the clamp if necessary until SUMO is released
when the knob is moved to position 1.
.
2
ENC.
3
4

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Su2000vSu2000vvSu2000

Inhaltsverzeichnis