Power socket requirements
12.1. DIN safety rules
DANGER
Electric Shock Hazard!
Modifications to the electrical installation may
only be carried out by qualified professionals. If
you are a qualified electrician, please observe
the 5 safety rules laid down in DIN VDE 0105:
Disconnect completely
Secure against re-connection
Check that power is off at all poles
Remember to ground yourself before
touching a component to prevent static
discharges!
Provide protection against adjacent live
parts
These five safety rules should be applied in the
above order before working on electrical
installations. Once the work is completed, they
are lifted in the reverse order.
12.2. Installation and sockets
The sockets in use have to be installed
correctly, especially regarding the quality and
the sequence of phase(s), neutral and PE,
regarding the diameter of the power supply. the
fuse, the RCDs etc.
The socket has to be free of defects and fully
dry.
User Manual JUICE BOOSTER 2 [EL-JB2, EA-JB2] Version 2.00 EN
All manuals and user guides at all-guides.com
12.3. Connection to the mains power
supply using adapters and
extension cables
DANGER
Electric Shock Hazard, Fire Hazard!
• Only use JUICE CONNECTOR safety
adapters from Juice Technology AG which
feature automatic current detection.
• Only use extension cables fitted with JUICE
CONNECTOR safety connectors and JUICE
CONNECTOR safety couplings from Juice
Technology AG. Use of other adapters and
extension cables can result in fatal electric
shock and/or fire. Moreover, the guarantee
becomes void.
• Only use correctly installed, properly
grounded power sockets fitted with neutral
conductors. If necessary, check the technical
specifications with the house owner or
building services. Only connect the device if
you are absolutely sure that the power socket
is in good condition.
• In many countries, industrial sockets must be
equipped with a Class A residual current
circuit breaker. JUICE generally recommends
the use of Class A RCDs for all types of
sockets. Please note the regulations in the
country of use, as these always take
precedence.
IMPORTANT: As JUICE BOOSTER 2 already
has integral residual current detection, you
don't have to allow for the considerable
expense of installing Class B or A (EV) RCD
systems.