Herunterladen Diese Seite drucken

pewag levo hook LH-Serie Originalbetriebsanleitung Seite 30

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
EN
Button/symbol
Open swivel hook
Close swivel hook
Hook lighting
(optional)
Status query
Button lock +
transmitting
signal*
Information
symbols
Charge status
display
pewag levo hook
LH battery charge
display
Status display
Remote control
battery level
Radio control unit
button lock
Contact with lifting
device (optional)
pewag levo hook LH
30
Description
Press this button to open the
swivel hook
Press this button to close
the swivel hook
Press this button to activate/
deactivate the light module
that is integrated in the
pewag levo hook LH.
The light will deactivate
automatically after a certain
period of time (depending
on the setting).
Press this button to receive
a status notification for the
connected hooks.
A keylock function is
available for the radio
control to prevent accidental
activation of keys.
To lock/unlock the radio
control, briefly press the
lighting and status buttons
simultaneously.
Description
Shows the charge status
of the pewag levo hook LH
battery. If only the red LED
lights up, please charge
the battery in the charging
station.
See description in
section 5.2
Indicates when the battery
of the remote control unit is
weak.
If this symbol lights up, the
keylock is activated.
The pewag levo hook LH
is in contact with the lifting
device.
The radio control unit comes with a factory preset medium
transmitting signal (range) of approx. 50 m. The transmitting
signal may be adjusted as follows: Hold down the status +
light button simultaneously until the battery status display on
the remote control begins to flash. Use the status query (+)
and hook lighting buttons (–) to adjust the transmitting signal.
If one green LED lights up, the transmitting signal is weakest.
If all LEDs light up, the transmitting signal is strongest. The
setting mode will terminate automatically after a certain period.
If the display ceases to flash, the setting mode terminates and
the new setting applies. Please note that a stronger transmitting
signal will shorten the lifespan of the integrated battery
(button cell).
5.4 Connecting the pewag levo hook
LH with the radio control unit
To operate the pewag levo hook LH with the radio control unit,
you must first connect the two devices. To do this, proceed as
follows:
1. Switch off the pewag levo hook LH. Hold down the on/off
button until the status display on the battery begins to flash.
The device is now in connection mode.
2. On the radio control unit, press the „status query" button
to perform the connection process When the connection
has been performed successfully, the status display on
the battery will give one long
flash. The radio control unit is
now connected. Section 2 may
be repeated for as many radio
control units as necessary.
3. To end the connection mode,
press the on/off button again.
This process must be completed
for every pewag levo hook LH and
every radio control unit
Please note that one radio control
unit may be connected with several
pewag levo hooks LH (= hook
network, see chapter 5.5). Several
radio control units may also be
linked to one or several pewag levo
hooks LH.
Fig. 5: Press for 3 seconds
Fig. 6: Press button „status query"
Fig. 7: Press to end