position. The battery may only be placed in the pewag levo
hook LH when the unit is switched off.
Important:
• Never try to insert or remove the battery when the fold-down
handle is set to the „Locked" position! This may damage the
locking mechanism.
• Do not use tools or other devices to insert or remove the
battery or to turn the fold-down handle.
• NEVER try to open or repair the battery unit or
to replace the battery cells!
5.2 First use
To activate the pewag levo hook LH, press the on/off button on
the battery (see table). As soon as the status display flashes,
the unit is ready for use.
On the battery/casing of the hook, you will find the following
buttons and information symbols:
* There are two potential reasons why the status display will
light up:
1. The device is malfunctioning
2. The test interval for the device has been exceeded
3. Weighing module (see section 5.4)
4. When switching on the unit
Button/symbol
On/off button
Charge status
display
Status display*
Battery lock
Open/close button
Description
Press this button to switch
the pewag levo hook LH
on or off.
Shows the charge status
of the battery. If all LEDs
light up, the battery is fully
charged. If only the red LED
lights up, please charge
the battery in the charging
station.
The status display provides
information on upcoming
inspections, errors or other
settings (see explanations in
the text*).
By turning the fold-down
handle clockwise by 90°,
the battery is locked in
the battery compartment.
Turn the handle counter-
clockwise to unlock the
battery compartment.
Opens/closes the swivel
hook. Do not reach into the
swivel range of the hook
as there is a risk of limbs
getting crushed.
5. Max. load is exceeded (5 tonnes)
6. Pre-defined settings are exceeded (e.g. weight, temperature)
In case of malfunctioning, try acknowledging the fault memory
by deactivating the device using the on/off button. Wait 10
seconds before reactivating the pewag levo hook LH. If the
status display no longer lights up, the error was temporary.
Continue using the device as normal. If the status display lights
up again immediately or after a short period, the device must
be inspected by pewag austria GmbH or by an authorised
pewag dealer and repaired as required.
For more information, see chapter 8, „Procedure in case of
accidents or faults" and chapter 9, „Cleaning, maintenance,
regular inspections".
5.3 Operating the levo remote
standard radio control
Using the radio control, it is possible to operate the pewag levo
hook LH within a radius of up to 100 m. Ideally, the pewag levo
hook LH should be within the operator's direct line of vision.
The battery provided must be inserted in the radio control unit
prior to first use. For detailed information on how to do this
correctly, see chapter 9.7, „Exchanging the battery in the levo
remote radio control".
You will find the following buttons and/or information symbols
on the levo remote:
The information symbols light up for short period when the
button „Status pewag levo hook LH" was pushed (exception:
„Radio control battery level" will light up when any button is
pushed).
*Adjusting the transmitting signal (reach):
Fig. 4: pewag levo remote
EN
pewag levo hook LH
29

Werbung

loading

Verwandte Produkte für pewag levo hook LH-Serie

Diese Anleitung auch für:

Levo hook lh4