Mounting
Mount the unit on a DIN rail or by means of a mounting fixture.
Mount the fibre optics:
1. Loosen the screw A.
2. Push the fibre optics into the sensor holes B until you feel a stop and
hold them.
3. Tighten the screw A.
A
B
If the fibre optics are not in contact with the internal optics, the
sensing range is reduced.
Electrical connection
Isolate the power, then connect the unit as specified (see the last
page or the type label).
• Core colours (for sensors with cable connection): BN = brown,
BU = blue, BK = black.
• Programming of the output function by wiring (see the page 15 or
the type label).