Setting of the switching threshold (2)
• Stationary objects
• Diffuse reflection fibre (FT ...) and through-beam fibre (FE ...)
The unit detects input signals of various intensity in any sequence and
calculates the optimum switching threshold.
1
Press until the red LED flashes.
Place the object into the
detection area.*
2
Remove the object.*
3
* You can also proceed in reverse order: first setting without the object, then
with the object.
If the setting of the switching threshold is not possible (e.g.
object signal and background signal are about the same), the red
LED flashes after step 3. The unit then passes into the operating
mode with the switching threshold being unchanged.
Operation
Only open the cover to make adjustments. Close it after the adjust-
ment has been made in order to maintain the protection IP65.
Check whether the unit functions properly.
10
Press once.
Press once.
Yellow and green LEDs
flash alternately
(= unit is in the
programming mode).
Yellow and green
LEDs go out for a short
time, then flash again
alternately.
Yellow and green
LEDs go out for a
short time,
then the green LED is on
(= unit is in the
operating mode).