Caution: At the last fixture, the DMX cable has to be terminated. Plug the terminator with a 120
between Signal (–) and Signal (+) in the DMX output of the last fixture.
Master/Slave-Operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the LED BR-200 you can find an XLR-jack and an XLR-plug, which can be used for
connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX cable. Connect the DMX
OUT jack with the DMX IN plug of the next device.
Please see further instructions under Operation.
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the device to the mains, the EUROLITE LED BR-200 starts running.
The LED display lights up and you can choose the desired mode via the buttons MODE, ENTER, UP and
DOWN.
The device has two operating modes. It can be operated in Stand Alone via LED display with operating
buttons or alternately in DMX-controlled mode via lighting controller.
You can adjust the microphone sensitivity with the rotary-control on the rearpanel.
STAND ALONE OPERATION
In the Stand Alone mode, the LED BR-200 can be used without controller. Disconnect the LED BR-200 from
the controller.