Models 36 / 42:
Indoor unit
Note:
- The connection wire of indoor units should be connected to the corresponding terminals board: otherwise it will cause
the unit failure or even damage the units.
- Connect the grounded wire correctly, otherwise will cause the malfunction of some electrical component and shock
or fire indeed.
- Don't reverse the power polarity.
- Must fix the screw nail of the firmly wire, then drag the wire lightly, confirmation whether it's firmly.
Wiring diagram of indoor unit:
WIFI MODULE
QRD-WIFI-SYE1
(Optional CL93565)
12V
TIMER
FAN
SWING
MODE
GND
FUNCTION
ON/OF
A
WIRED CONTROLLER
XK-05
B
(Optional CL93920)
Operation of remote ON/OFF:
The operation is as follows:
1) With the unit running if the contact opens unit stops and remote control is locked.
2) With the unit stoped if the contact opens unit will continue stop and remote control is locked.
NOTE: To use this function this function you have to set the parameter "0901" see next page.
Outdoor unit
WIFI
X1 (red)
X2 (black)
485-BUS1 (2)
X3 (green)
X4 (yellow)
4 wires
(50mts max.)
A
Outdoor unit
interconnection
Models 36 to 60
Models 48 / 60:
Indoor unit
MAIN PCB
L(L1) N(L2) S
Outdoor unit
B
interconnection
Models 12 to 30
53
Outdoor unit
Remote ON/OFF
ID1
The terminals that are between dashed
lines is optional its use
L
220-240V, 50Hz, 1-

Werbung