• The boiling water storage heater must be placed
in an upright position.
• The boiling water storage heater must not be
directly or indirectly sprayed with water when
cleaning.
• The boiling water storage heater must not be
opened.
• Use only genuine replacement parts and
accessories. The use of other parts will result in
voiding the warranty and the CE marking, and
could cause injury.
• Do not use a damaged device.
• The filter head must be replaced after 5 years by
the GROHE service.
• The use of extension cables is not permitted
between the electrical socket and boiling water
storage heater connection.
• The boiling water storage heater must be used
with the safety assembly supplied.
• To ensure uninterrupted function of the safety
assembly, it is advisable to have maintenance
work carried out regularly.
• The boiling water storage heater may only be
used with a GROHE Red fitting.
• Do not connect the hot water connection of the
fitting to the hot water outlet of the storage
heater. A mixing valve must be used (special
accessory *40 841), as necessary.
• If the operating pressure is insufficient, the
boiling water storage heater must be switched
off.
• In order to transport the boiling water storage
heater, it must first be emptied. To do this, the
safety assembly must be disconnected from the
boiling water storage heater.
Caution: risk of scalding. Escaping water is
boiling hot.
• No liability can be accepted for damage that
occurs due to non-observance of the operating
instructions.
15
Technical data boiling water storage heater:
• Connection:
• Installation elevation:
• Voltage supply:
• Max. power consumption:
• Type of protection:
• Relative humidity:
• Ambient temperature:
• Standby power loss (switched on):
• Standby power loss (holiday mode):
• Standby power loss (switched off):
• Energy efficiency class:
Sanitary data:
• Boiling water storage heater capacity:
• Available storage heater volume at 100 °C:
• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
• Flow rate at 0.3 MPa flow pressure
- mixed water:
- boiling water:
• Boiling water temperature:
The actual temperature may differ slightly
due to different ambient pressures.
• Heating time from 10 °C to 100 °C:
• Clamping length of fitting:
• Water connection to storage heater:
• Water connection fitting:
The filter system with ion exchanger (S, M, L or Mg+) which is
included must be used in regions with a carbonate hardness
exceeding 10 °KH. The relevant water supplier can provide
information on the carbonate hardness.
Thermal disinfection of the fitting is possible.
Confirmation
Status
Initialisation
Heating phase
Ready for operation
Holiday mode, cooling-down
phase
Holiday mode
Defects
wall socket with earth wire,
protected via a 10 A fuse
max. 2000 m above sea level
230 V AC / 50 Hz
max. 95 %
M: approx. 3 l
L: approx. 5.5 l
0.2–0.5 MPa
max. 0.8 MPa
approx. 6 l/min
approx. 3 l/min
M: approx. 20 min
L: approx. 30 min
max. 60 mm
cold water
cold/hot water from the service valve
boiling water from storage heater
Storage heater LED
white
red, flashing
red, continuous
orange, flashing
orange, continuous
agenta, flashing/continuous
2200 W
IP X4
0–40 °C
M: 14 W
L: 15.7 W
M: 5 W
L: 7 W
1 W
A
M: 4 l
L: 7 l
0.2 MPa
1.6 MPa
100 °C

Werbung