Firing of glazing:
1st program phase
=
2nd program phase
=
3rd program phase
=
Specifications:
Safety category
Voltage
Permitted ambient temperature
Probe
Precision
Breaking capacity
Output
Range of control
Dimensions
Weight
Subject to technical modifications.
Hobbygross Erler GmbH
Große Ahlmühle 10
76865 Rohrbach
Germany
Tel.
++49 6349-9934-0
Fax
++49 6349-9934-26
heating-up phase
heating-up rate 200 °C per hour
up to 100 °C (thus duration = 30 minutes)
heating-up to firing temperature, e.g. 1,050 °C
without delay
holding time of the firing temperature, e.g. 15 minutes
1
230 V
max. 45 °C
NiCr-Ni or PtRh-Pt
+/- 0,5%, +/- 1 digit
max. 3,500 W
230 V, 50 c.p.s.
20 - 1,200 °C (Observe the max. kiln temperature!)
or 20 - 1,300 °C (Observe the max. kiln temperature!)
H - 135 mm, W - 230 mm, D - 170 mm
controlling device: approx. 3,000 g
probe: approx.
270 g
(press SET 3 x)
(press SET 2 x)
(press SET 4 x)