Description:
The TRP 010 controlling device is an automatic process controlling device with a digital display for actual and set values.
A thermocouple in accordance with DIN 43 710 serves as a sensor (supplied with the device).
The TRP 010 controlling device is particularly suited for controlling the temperature of kilns for enamelling, melting, annealing and
tempering as well as for firing ceramics, porcelain etc. These controlling devices are used whenever temperatures are to be regu-
lated over three phases (heating-up, full load, maintaining temperature).
The kiln is directly plugged into the socket of the controlling device, which switches the kiln to an output of up to 3,500 Watts at
230 Volts (resistive load).
Putting into Operation:
The kiln may only be operated in a dry, well ventilated room on a fire-proof base. The safety distances to the potentially combu-
stible environment are to be observed.
Connection:
1. Plug the earthed plug of the kiln into the socket on the back of the controlling device.
2. Push the temperature probe (thermocouple) into the hole provided for it in the kiln (back). The probe should be introduced into the
firing chamber so that the tip reaches the centre of the chamber (while doing so the fragility of the ceramic tube should be taken into
consideration). The diode plug of the probe is plugged into the socket on the back of the controlling device. Please note that it only fits
in one position.
3. Insert the earthed plug of your controlling device into the 230 Volt socket earthed in accordance with the regulations.
1
2
3
Important:
The TRP 010 temperature controlling device is manufactured in accordance with safety category 1 and may only be inserted in a
mains socket (230 V) that is equipped with the corresponding earthed contact.
The controlling device may not be placed upon the kiln!
Thermocouples (temperature probes):
An NiCr-Ni element, conceived for constant temperatures from 1,100 °C to 1,150 °C, is supplied with the 1,200 °C type. It may be used
at 1,200 °C only for a short time, since otherwise signs of wear appear too soon. The thermocouple or broken tube must be replaced
when defective.
If there is a defect or if the probe is not connected, the device indicates error E-05.
After the red control switch has been switched on, the display segments of the controlling device light up first of all and then the current
controlling software is displayed. Then the set temperature is indicated in red at the bottom and the current actual temperature in yel-
low at the top for the first program phase (heating-up phase). To select the first section of the programme press the Set button once.
The set value can be changed by pressing keys 2 and 3. If a key is held down for a certain time, the values are changed at fast speed.
Press the SET key two times to select the second program phase. "Setpoint 2" is now indicated in yellow at the top and the firing tem-
perature in red at the bottom. Once again any changes can be made with the
How to use the controlling device
1
Heating signal lamp (LED C1)
6
2
Increase value
3
Decrease value
5
4
SET key (select program phase)
5
Indicator for the set value
4
6
Indicator for the actual value

Werbung