Battery Voltage Parameters
These values apply to a 12V system at 25°C. For a 24V system the values must be doubled.
Battery Type
Overvoltage disconnect
Max. charging voltage
Restart after voltage
Equalize load voltage
Boost load voltage
Float load voltage
Boost-restart load voltage
Under voltage restart
Under voltage warning
Restart
Voltage
Under voltage warning
Under voltage disconnect
Discharge threshold voltage
Equalizing period
Boost period
PWM Pro 12/24
Sealed
16.0V
15.0 V
15.0 V
14.6 V
14.4 V
13.8 V
13.2 V
12.6 V
12.2 V
12.0 V
11.1 V
10.6 V
120 min
120 min
— 22 —
10A | 20A | 30A | 45A
Gel
Flooded
16.0V
16.0V
15.0 V
15.0 V
15.0 V
15.0 V
– –
14.8 V
14.2 V
14.6 V
13.8 V
13.8 V
13.2 V
13.2 V
12.6 V
12.6 V
12.2 V
12.2 V
12.0 V
12.0 V
11.1 V
11.1 V
10.6 V
10.6 V
– –
120 min
120 min
120 min