b) Switch the Power Supply OFF
Before installation, switch the electricity supply and corresponding circuit breaker and/or
automatic fuse OFF.
Secure against unauthorized restart, e.g. by installing a warning sign.
Check the power circuit for remaining voltage using an appropriate measuring device.
Pay attention to the "Safety Instructions" section.
c) Connect Power Supply Leads
Remove the outer insulation on the wires to a
maximum length of about 16 mm.
Strip the insulation on each main cable wire to a length
of about 6 mm.
Loosen the screws in the connection terminal (9) then connect power supply leads as shown in the
wiring diagram.
Tighten the connection terminal (9) screws.
Check that the cables are not squeezed, bent or damaged in any other way.
Adjust the rotary controls TIME (6), SENS (5), and LUX (4); refer to "Operation" for further instructions.
d) Attach the Faceplate
Align the brightness sensor (11) with the cut-out on the faceplate (2), then press together
e) Switch the Power Supply ON
Turn the corresponding circuit breaker and/or automatic fuse back ON.
If the sensor does not function correctly, immediately turn the circuit breaker OFF and/or automatic fuse.
Check the connection to the power circuit.
Operation
a) Switch Settings (ON / OFF / AUTO)
ON: Power to connected load is always ON, independent of LUX (4) and
SENS (5) settings.
OFF: No power to connected load.
AUTO: Power to switch is triggered by motion detection, depends on LUX
(4) and SENS (5) settings.
b) Adjusting Motion Detection
The motion detector has three rotary controls that
can be used to change the switch-on time TIME (6),
sensitivity SENS (5), and the switch-on threshold for
ambient light levels LUX (4).
c) "TIME" (Switch-On Time)
You can set a switch-on time to control how long the connected the load stays on.
Rotating the TIME (6) dial counter-clockwise will decrease the duration. Rotating clockwise will increase
the duration.
Settings include 10 seconds (±3 seconds) up to 12 minutes (±1 minute).
If new motion is detected during the switched-on time, the timer will reset and start again. The
consumer will stay switched on.
d) "SENS" (Sensitivity)
You can adjust the motion detection sensitivity levels.
Rotating the SENS (5) dial counter-clockwise "-" will decrease sensitivity, Rotating clockwise "+"
increases it.
- Decreasing sensitivity reduces the sensor detection range.
- Increasing the sensitivity expands the range.
e) "LUX" (Brightness Setting)
You can adjust the switching threshold based on ambient light levels.
Rotating LUX (4) counter-clockwise activates motion detection when it gets dark.
Rotating LUX (4) clockwise towards the sun
f) Function Test
To optimize the sensor settings so that the connected load is triggered under the desired conditions, you may
need to perform a function test.
Set the time TIME (6) to the minimum duration 10S.
Set the light LUX (4) level to the highest setting
Set the motion detection sensitivity SENS (5) to the middle setting.
Walk across the detection area. The motion detector will activate the connected load if it detects a
movement within the detection area.
If needed, fine tune the rotary controls after the functional test.
10 mm
symbol activates motion detection in brighter conditions.
.
Troubleshooting
Problem
Suggestion
Check the setting for the the brightness control LUX (4). If it is too low it will activate
in the dark.
Check if there is a power supply and if the connected device (i.e. a bulb) functions
The connected
correctly.
load does not
Increase the motion detection sensitivity SENS (5).
switch on.
Movements within the detection area are too rapid, and are filtered out by the
electronic system, in order to prevent switching errors.
The switch (10) may be in the OFF position. Set it to ON or AUTO.
6 mm
Constant movements occur within the detection area; this may also be a
movement in the adjacent room due to the HF technology used. Decrease the
The connected
motion detection sensitivity level SENS (5).
load is always
New movement is detected before the previous switch on time TIME (6) has
on.
elapsed. Try setting a shorter switch on time.
The switch (10) may be in the ON position, set it to OFF or AUTO.
Care and Cleaning
The product is generally maintenance-free. Any
repair or maintenance work must be carried out
by a specialist.
Do not use any aggressive cleaning agents,
rubbing alcohol or other chemical solutions as
they can cause damage to the housing and
malfunctioning.
Clean the product with a dry, fibre-free cloth.
Declaration of Conformity (DOC)
Conrad Electronic SE, Klaus-Conrad-Straße 1,
D-92240 Hirschau hereby declares that this product
conforms to the 2014/53/EU directive.
Click on the following link to read the full
text of the EU declaration of conformity:
www.conrad.com/downloads
Select a language by clicking on a flag
symbol and enter the product order
number in the search box. You can
then download the EU declaration of
conformity in PDF format.
Disposal
Electronic
devices
waste and must not be disposed of in
the household waste. At the end of its
service life, dispose of the product in
accordance with applicable regulatory
guidelines. You thus fulfill your statutory
obligations and contribute to the
protection of the environment.
Technical Data
a) General
Input voltage ................................ 220-240 V/AC,
Static power consumption ...........0.63 W
Working power consumption .......1.36 W
Rated load ................................... max. 1200 W
Devices with resistive loads include light
bulbs, heaters, etc.
Devices with inductive loads include
engines, control gears (e.g. for LEDs),
conventional
saving bulbs, etc.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights
including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represent the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE.
Detection angle ............................180º
Installation height .........................1 - 1.8 m
Detection motion speed ...............0.6 - 1.5 m/s
Detection distance ....................... 5 -15 m
HF system ................................... 5.8 GHz, CW
Switch-on time ............................. 10 - 90 s (±3 s),
Light levels (lux) ........................... 0.1 / 3 / 30 / 300 /
Material ........................................PC
Operation current .........................24 mA
Protection type .............................IP20
Installation location ...................... Dry enclosed
Frequency ........................................ 5.725 – 5.875 GHz
Transmission power.....................<10 mW
Protection class ...........................2
Operating/storage conditions ....... -20 to +50 ºC,
Internal bore ................................ø5.5 mm
are
recyclable
Product dimensions ..................... 80 x 80 x 32 mm
Product weight .............................100 g
b) Dimension Drawing
50 / 60 Hz
(resistive)
max. 300 W
(inductive)
50 mm
transformers,
energy
(adjustable)
radar, ISM band
3 - 12 min (±1
min)
2000
rooms
<93 % RH
(non-condensing)
(W x H x D)
32 mm
80 mm
*2108038_v3_0520_02_dh_m_en

Werbung

loading

Diese Anleitung auch für:

Rf-4216076