Function and features
• The pressure sensor detects the system pressure,
• shows the current system pressure on its display,
• and generates 2 output signals according to the set output
configuration.
Analogue output
(only output 2)
Switching function
(output 1 and output 2;
function can be selected for
each output separately)
Output polarity (applies to both
switching outputs)
Applications (Type of pressure: relative pressure):
Order no.
bar
PF2653
PSI
MPa
bar
PF2654
PSI
kPa
bar
PSI
PF2656
kPa
mbar
PF2657
PSI
kPa
bar
PF2609
inHg
kPa
Measuring
range
-1.0 ... 25
-15 ... 363
-0.1 ... 2.5
-0.5 ... 10
-7 ... 145
-50 ... 1 000
-0.13 ... 2.50
-1.8 ... 36.3
-13 ... 250
-50 ... 1 000
-0.7 ... 14.5
-5.0 ... 100
-0.99 ... 1.00
-30 ... 30
-99 ... 100
Output 1
hysteresis function / N.O. (Hno)
hysteresis function / N.C. (Hnc)
window function / N.O. (Fno)
window function / N.C. (Fnc)
p-switching (PnP)
n-switching (nPn)
Permissible
overl. pressure
100
1 450
10
50
725
5 000 (5 MPa)
20
290
2 000 (2 MPa)
10 000 (10 bar)
145
1 000 (1 MPa)
20
590
2 000 (2 MPa)
Output 2
I: 4 ... 20 mA
U: 0 ... 10 V
Bursting
pressure
350
5 070
35
150
2 175
15 000 (15 MPa)
50
725
5 000 (5 MPa)
30 000 (30 bar)
450
3 000 (3 MPa)
50
1 475
5 000 (5 MPa)
21