Daily Use
Troubleshooting
Caution! Before troubleshooting, disconnect the power supply. Only a qualified electrician
of competent person must do the troubleshooting that is not in this manual.
Important! There are some sounds during normal use (compressor, refrigerant circulation).
Problem
Appliance does not work
Appliance freezes or cools too
much
The food is not frozen enough
Heavy build up of frost on the door
seal
Unusual noises
Indicator lights flashing
If the malfunction shows again, contact the Service Center.
Possible cause
Mains plug is not plugged in or is
loose
Fuse has blown or is defective
Socket is defective
Temperature is set too cold
Temperature is not properly
adjusted
Door was open for an extended
period
A large quantity of warm food was
placed in the appliance within the
last 24 hours
The appliance is near a heat source
Door seal is not air tight
Appliance is not level
The appliance is touching the wall or
other objects
A component, e.g. a pipe, on the
rear of the appliance is touching
another part of the appliance or
the wall
Sensor fault
Solution
Insert mains plug
Check fuse, replace if necessary
Mains malfunctions are to be cor-
rected by an electrician
Turn the temperature regulator to a
warmer setting temporarily
Please look in the initial Tempera-
ture Setting section
Open the door only as long as
necessary
Turn the temperature regulation to
a colder setting temporarily
Please look in the installation loca-
tion section
Carefully warm the leaking sections
of the door seal with a hair dryer
(on a cool setting). At the same
time shape the warmed door seal
by hand such that it sits correctly
Re-adjust the feet
Move the appliance slightly
If necessary, carefully bend the
component out of the way
Inform the maintenance center