Alarmmeldungen

Number
Message
40300
RS-485 communica-
tion alarm.
40301
RS-485 communica-
tion alarm.
40302
Active interface
(Modbus or Web-
GUI) communica-
tion timeout has
occured
40303
RS-485 communica-
tion alarm.
40304
No slave module
was found, please
check RS-485 con-
nection(s).
40305
Number of or combi-
nation of connected
slave types not sup-
ported.
40412
Software versions
of system control
and module(s) do
not match.
40413
Software versions
of system control
and module(s) do
not match.
40414
Software versions
of system control
and module(s) do
not match.
40415
Software versions
of system control
and module(s) do
not match.
40416
Software versions
of system control
and module(s) do
not match.
50000
Overtemperature
IGBT bridge 1.
50001
Overtemperature
IGBT bridge 2.
50002
Overtemperature
IGBT bridge 3.
A67-0141-00.BKde-0
01-10
Effect
No operation possi-
ble.
No operation possi-
ble.
No operation possi-
ble.
No operation possi-
ble.
System cannot
finish start-up proce-
dure
System cannot
finish start-up proce-
dure
System cannot
finish start-up proce-
dure
System cannot
finish start-up proce-
dure
System cannot
finish start-up proce-
dure
System cannot
finish start-up proce-
dure
System cannot
finish start-up proce-
dure
No operation possi-
ble.
No operation possi-
ble.
No operation possi-
ble.
2023-07-10
Cause
Action
Communication pro-
Check RS-485 com-
blem on RS-485
munication.
bus.
Communication pro-
Check RS-485 com-
blem on RS-485
munication.
bus.
Active interface
Check active inter-
(Modbus or Web-
face (Modbus or
GUI) communica-
WebGUI) or disable
tion timeout has
timeout.
occured
Communication pro-
Check RS-485 com-
blem on RS-485
munication.
bus.
No slave module
Check RS-485 con-
was found.
nection(s) and
modules.
Number of or combi-
Check module confi-
nation of connected
guration. Only
slave types not sup-
homogeneous
ported.
modules are allo-
wed on one
RS-485 bus.
Software versions
Software update
of system control
necessary.
and module(s) do
not match.
Software versions
Software update
of system control
necessary.
and module(s) do
not match.
Software versions
Software update
of system control
necessary.
and module(s) do
not match.
Software versions
Software update
of system control
necessary.
and module(s) do
not match.
Software versions
Software update
of system control
necessary.
and module(s) do
not match.
Overtemperature
Check the fan and
IGBT bridge 1.
the ambient tempe-
rature.
Overtemperature
Check the fan and
IGBT bridge 2.
the ambient tempe-
rature.
Overtemperature
Check the fan and
IGBT bridge 3.
the ambient tempe-
rature.
Detec-
ted by
System
control
System
control
System
control
System
control
System
control
System
control
System
control
System
control
System
control
System
control
System
control
AC-DC
module
AC-DC
module
AC-DC
module
137
Fehlersuche

Werbung

Inhaltsverzeichnis
loading