7 Troubleshooting
Problem
Cause
Measurements
There is a poor
from the outdoor
connection
sensor are not
between the
displayed or are
outdoor sensor and
displayed only
the base station
intermittently
The outdoor sensor
was not detected
Implausible
The outdoor sensor
readings
is not positioned
correctly
8 Cleaning and care
Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions.
They damage the housing and can cause the product to malfunction.
– Do not immerse the product in water.
Clean the product with a fibre-free cloth.
9 Disposal
9.1 Product
This symbol must appear on any electrical and electronic equipment placed on the
EU market. This symbol indicates that this device should not be disposed of as
unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back
of waste. Conrad provides the following return options free of charge (more details on our
website):
in our Conrad offices

at the Conrad collection points

at the collection points of public waste management authorities or the collection points set

up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in
countries outside of Germany.
9.2 (Rechargeable) batteries
Remove batteries/rechargeable batteries, if any, and dispose of them separately from the
product. According to the Battery Directive, end users are legally obliged to return all spent
batteries/rechargeable batteries; they must not be disposed of in the normal household waste.
Batteries/rechargeable batteries containing hazardous substances are labelled with
this symbol to indicate that disposal in household waste is forbidden. The abbrevia-
tions for heavy metals in batteries are: Cd = Cadmium, Hg = Mercury, Pb = Lead
(name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our
stores or wherever (rechargeable) batteries are sold. You thus fulfil your statutory obligations
and contribute to environmental protection.
Batteries/rechargeable batteries that are disposed of should be protected against short circuit
and their exposed terminals should be covered completely with insulating tape before disposal.
Even empty batteries/rechargeable batteries can contain residual energy that may cause them
to swell, burst, catch fire or explode in the event of a short circuit.
10 Declaration of Conformity (DOC)
Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau hereby declares that this
product conforms to the 2014/53/EU directive.
Click on the following link to read the full text of the EU declaration of conformity:

www.conrad.com/downloads
Enter the product item number in the search box. You can then download the EU declaration of
conformity in the available languages.
Solution
Turn the outdoor sensor and base station off
and then back on again
Make sure you are using the correct power
supply
Make sure the selected channel is the same
on the base station and the outdoor sensor
Position the outdoor sensor near the base
station to establish a connection
Ensure that the outdoor sensor is within range
(max. 100 m)
Make sure there are no nearby sources
of interference (e.g. radio masts, wireless
electrical devices etc.)
Place the base station and outdoor sensor in
a suitable location (no direct sunlight, not in
the vicinity of heat sources etc.)
11 Technical data
Power supply ........................................ 2x 1.5 V AA batteries
Measurement range ............................. -40 to +60 ºC, 1 – 99 % RH
Transmission frequency........................ 433.05 - 434.79 MHz
Transmission power.............................. 4.11 dBm
Range ................................................... max. 100 m
Operating/storage conditions ................ -40 to +60 ºC
Protection rating (outdoor sensor) ........ IP54
Dimensions (W x H x D) ....................... 112 x 165 x 27 mm
Weight .................................................. 427 g (base station)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-
cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represents the technical status at the time of printing.
Copyright 2023 by Conrad Electronic SE.
*2806245_v1_0923_02_dh_mh_en

Werbung

loading