Herunterladen Diese Seite drucken

AquaMedic AT-Control Schnellanleitung Seite 7

Verfügbare Sprachen

Verfügbare Sprachen

With "On" and "Off" intervals can be set. To program the lighting, these values are kept at 0. The
days of the week can be switched on or off by the arrow keys.
From the main menu, you can move to the measuring parameters like pH, ORP (Redox)
conductivity, density. If you move the cursor down, more parameters are shown.
The adjustion is the same for all parameters:
You choose in the main menu the line "Temperature" With Enter you go to "programs" and to
"Insert".
____
Temperature______
Insert
Fig. 10
With the → ←- keys you move the cursor, with the ↓↑ keys, you adjust the values.
With ∆MIN and ∆MAX the temperature difference for switching can be programmed. This is the
difference between the set point and the switch on point for heater or cooler. Example: the set
point is 25°C and the ∆MIN is 0.2°C. The heater now switches on at 24.8°C and off at 25°C.
To program the plugs for the heater or cooler, choose the line "plugs". The following screen is
shown:
2
UP01
1
2
UP01
1
2
Fig. 12
In the basic menu, the temperature icon appears above the chosen plug, if the plug is switched on.
If the plugs are programmed, leave the program menu with "ESC" and "confirm". By pressing
"ESC" several times, you return to the basic menu.
The programming of pH, ORP (Redox) conductivity, density and level can be done in the same way.
Calibration of the pH value
Switch off all electrical units, activated by the pH Control (solenoid valves or dosing pumps), as
they may be switched on during the calibration procedure.
The screen shows the plugs 1 – 6 of the Power Box
UP01. With the arrow keys, you choose the plug, e. g.
for programming the heater. Here, plug 2 is chosen
3
4
5
6
(see 1st line). You choose the upper line of the plugs to
program a cooler (to act if the value is higher than the
set point ) and the lower line to program a heater (to
3
4
5
6
act if the value is lower than the set point).
To program a heater on plug 2 press the arrow key ↓.
The thermometer icon appears above plug 2, lower line.
The cooler can be programmed in the same way:
choose a plug, confirm with ↑. Now the thermometer
icon appears above the No. of the plug in the upper line
(here No. 5 ). Now a heater can be connected to plug
2, a cooler to plug 5.
______
Programs_______
Ref.
∆ MIN:
0.0°C
plugs
Fig. 11
23.4°C
∆Max:
0.0°C
confirm
7
loading

Verwandte Produkte für AquaMedic AT-Control