Fault
Temperature differs
greatly from the set
value.
Freezer compartment
door was open
for a long time;
temperature is no
longer reached.
Appliance is not
cooling, temperature
display and light
are lit.
Possible cause
The evaporator
(refrigeration
generator) in the
No Frost system
is covered in thick ice
and can no longer
be defrosted fully
automatically.
Showroom mode is
switched on.
Remedial action
In some cases it is adequate
to switch off the appliance
for 5 minutes.
If the temperature is too high wait
a few hours and check whether
the temperature has approached
the set value.
If the temperature is too low check
the temperature again the next day.
To defrost the evaporator,
remove the frozen food with the
compartments, insulate well and
store in a cool location.
Switch off the appliance and move
it away from the wall.
Leave the appliance door open.
After approx. 20 min.
the condensation begins to run
into the evaporation pan,
at the rear of the appliance. Fig. 8
To prevent the evaporation pan from
overflowing in this case, mop up the
condensation with a sponge.
The evaporator is defrosted when
the water stops running into the
evaporation pan. Clean the interior.
Switch the appliance back on again.
Hold down temperature selection
button fig. 2/4 for 10 seconds until
an acknowledgement signal sounds.
After a short time check whether
your appliance is cooling.