Fig 15
Fig 16
Address switch 1
0
0
0
...
1
1
...
...
2
2
...
2
Fig 17
14
RZ 5000 ..., RZ 5001 ...,
RZ 5000 ..., RZ 5001 ...,
RZ 5000 ..., RZ 5001 ...,
RZ 5000 ..., RZ 5001 ...,
RZ 5000 ..., RZ 5001 ...,
RZ 5004 ..., RZ 5024 ...
- Dismount side parts and
reflector
- Dowel enclosure with two
screws
- Connect mains to terminals
L (U), N (0) and PE
- Address luminaire (see
chapter 5)
- Insert reflector, lamps and
cover
- Mount side parts
- Mark luminaire
5. 5. 5. 5. 5. Addressing
Addressing
Addressing
Addressing
Addressing
Before fitting the screen or
bowl, the addressing of the in-
dividual luminaires will have to
be performed. To do so, the de-
sired address (1 - 20) is set on
the address switch by means of
a suitable screw driver (Arrow-
head to No., fig. 15, 16, 17). If
the luminaire should not be
monitored the code 0/0 has to
Address switch 2
0
1
2
...
0
1
...
...
0
1
...
9
Luminaire address
Monitoring off
1
2
...
10
11
...
...
20
not permissable
not permissable
be selected. Luminaires without
CG-monitoring do not have ad-
dress switches and will not be
addressable.
6. 6. 6. 6. 6. Function test
Function test
Function test
Function test
Function test
After complete installation a
functional test of the whole
system is required.
7. Servicing/Maintenance
7. Servicing/Maintenance
7. Servicing/Maintenance
7. Servicing/Maintenance
7. Servicing/Maintenance
Observe the relevant national
regulations which apply to the
maintenance, servicing and
check of electrical apparatus!
On condition of an appropriate
operation and of observing the
mounting instructions and en-
vironmental conditions, no per-
manent servicing will be re-
quired.
For replacement of the lamp
see chapter "Installation"
8. Disposal/Recycling
8. Disposal/Recycling
8. Disposal/Recycling
8. Disposal/Recycling
8. Disposal/Recycling
When a defective apparatus is
disposed of, the respective na-
tional regulations on waste dis-
posal and recycling will have to
be observed. Plastic parts have
been provided with respective
symbols.