Following the above preparations, you should first turn on the pump
cooperating with the sterilizer. Make sure that the hoses are tightly
connected to the sterilizer. If leaks are discovered, tighten up the con-
nections. Only after stabilizing the water flow, turn the sterilizer on by
sticking the plug in a power outlet.
The sterilizer is designed for continuous operation. Expected period
of effective operation of the UV-C fluorescent lamp is approximately
10,000 hours. After the lapse of the planned period of operation, the UV-C
sterilizer should be turned off, by pulling the plug from the power supply
socket.
ATTENTION! The device is equipped with a safety switch (mi-
croswitch) to protect the user from the harmful effects of possible ex-
posure to UV-C light. The moment the holder in the steriliser housing
(7) is turned on, the lamp is automatically switched off (the lamp in the
steriliser housing outside the steriliser module DOES NOT LIGHT).
Before starting the appliance, make sure that the socket is screwed
on as tight as possible and forms a single unit with the housing (7).
For efficient operation of the sterilizer, it should be cleaned every several
weeks, performing the following actions:
1. disconnect the device and the pump cooperating with it from the
power supply by pulling the plugs from the sockets,
2. disconnect the device from the waster circulation and remove any
water remaining in it,
3. remove the luminaire with the fluorescent lamp by turning it anticlock-
wise,
4. carefully remove the quartz cover (8) by gently sliding it out of the
lamp body (7) and rinse it under running water and carefully wipe it
dry – especially its inner side,
5. screw out the stub pipes (5) and stopper (3), remove the gaskets (4)
from them, and carefully clean under running water,
6. clean the housing,
7. assemble the device in reverse order, all gaskets must be properly
placed in their groove and greased with Vaseline, and the fluorescent
lamp must be inserted all the way into the fitting until refusal.
FLUORESCENT LAMP REPLACEMENT
When the UV-C fluorescent lamp does not work it should be replaced
as follows:
1. disconnect the device by pulling the plug from the power supply
socket,
2. disconnect the device from the water circulation, remove any remain-
ing water inside and wipe dry,
3. turn the holder handle counterclockwise,
4. remove the fitting,
5. remove the fluorescent lamp from the fitting (9) and press a new one
LAUNCH AND USAGE
CLEANING THE STERILIZER
STERILIZERUV
13