FS100...-2LI-...
EN
Quick Start Guide
Technical Data
Electrical data – general
Application area
FS1...-...L: liquid media
Ambient temperature
-25...+85 °C
Medium temperature
-25...+85 °C
Pressure resistance
300 bar
Operating voltage
17...33 VDC
Power consumption
≤ 1.5 W
Output function
4...20 mA, analog
Output 1
Flow: analog
Output 2
Temperature: analog
Protection class
IP6K6K/IP6K7/IP6K9K acc. to ISO 20653
Electromagnetic compatibiliy (EMC)
EN 61326-2-3
Shock resistance
50 g (11ms), EN 60068-2-27
Vibration resistance
20 g, EN 60068-2-6
UL condition: Minimum temperature rating of the cable to be connected to the field wiring
terminals, 105 °C (221 °F).
Hans Turck GmbH & Co. KG | Witzlebenstraße 7, 45472 Mülheim an der Ruhr, Germany | Tel. +49 208 4952-0 | Fax +49 208 4952-264 | more@turck.com | www.turck.com
Operating range
Flow monitoring – FS1...-300L
Operating range
1...300 cm/s
Temperature monitoring
Measuring range
-25...+85 °C
Factory settings
FS1...
Indication mode
MAX/MIN Mode
MIN Teach
Minimum
MAX Teach
Maximum
Ø 38
96.4
Electrical
connection
41.3
M18 x 1.5
22
9.5
M18 x 1.5
Process
ø 8.5
14.5
connection
L1
L
ø 7.3
Wiring Diagrams
1 L+
BN
2
4 out 1
I
BK
I
2 out 2
WH
3
1
3 L–
BU
4
out 1: Flow
out 2: Temperature
FS100-...-2LI-H1141
BN L+
BK out 1
I
WH out 2
I
BU L–
out 1: Flow
out 2: Temperature
FS100-...-2LI-2M
© Hans Turck GmbH & Co. KG | 100002657 2020-12 | DE EN