Herunterladen Diese Seite drucken

Atag One zone Bedienungsanleitung Seite 26

Vorschau ausblenden Andere Handbücher für One zone:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Technical specifications
Power supply
Current draw
Operating temperature
Storage temperature
Humidity
Temperature reading precision
Bus wire length and cross-sectional area
NOTE: TO AVOID INTERFERENCE PROBLEMS, USE A SHIELDED CABLE OR
TWISTED PAIR CABLE.
Insulation class
Protection rating
Dimensions
Frequency band used
Maximum power in the band
Wi-Fi channel
Product card (with ATAG zone bus system only)
Supplier name
Supplier identification model
Temperature control class
Energy efficiency contribution (%) for space heating
With an optional outdoor sensor or internet weather data:
Temperature control class
Energy efficiency contribution (%) for space heating +4%
In a system with 3 zones and at least 2 room controllers:
Temperature control class
Energy efficiency contribution (%) for space heating
26
BUS (8 to 24V max)
≤60mA
0 to 40°C
-20 to 70°C
20% RH to 80% RH
+/- 0.5°C
max. 50 m
ø min. 0.6 mm²
III
IP 20
103mm x 103mm x 18.1mm
2400 MHz - 2483.5 MHz
+19 dBm - 802.11 b, g, n
1-13
ATAG
ATAG One Zone
V
+3%
VI
+4%
VIII
+5%

Werbung

loading